Cirugía de Columna y Articulaciones
Cirugía de Columna y articulaciones
Cirugía de Columna y Articulaciones
miércoles, 9 de julio de 2014
Discusión entre pares/Give ur expert comment plzzz
Indian-Orthopaedic Research-Group
Dhaval Patel
Indian Orthopaedic Research Group
Give ur expert comment plzzz
Me gusta
Anoop R. Nair
Good attempt
1. Intra articular step not acceptable
2. Plate is not contoured to lateral surface of femur so there is a medial shift of condylar part compared to shaft ..basic anatomy is distorted by this fixation.
All the best.
5 horas
·
Me gusta
·
3
Drmahesh Dama
Intraarticular. Step.
5 horas
·
Me gusta
P Rajasekhar Rao
that inraarticular step is at non weight bearing area
4 horas
·
Me gusta
Godspeed M. Khawlhring
possible improvement: plate contouring and proper interfrag screws of distal fragments. btw, this is a difficult case and achieving ideal fixation may be difficult.
4 horas
·
Editado
·
Me gusta
·
1
Yazan J. Hattar
should have been done with LISS rather than a complete open. Medial cortex comminution needs grafting. plate should have been longer with more empty holes left to allow dynamization of the construct
3 horas
·
Me gusta
·
1
Dhaval Patel
Defect was filled by primary bone graft from ileum ..
3 horas
·
Me gusta
Mithilesh Kumar
Always do on ortho table with sufficient amount of skeletal traction and under c arm.
3 horas
·
Me gusta
·
1
Ramesh P Singh
Longer plate with less screw.
3 horas
·
Me gusta
·
1
Vikas Mehra
There is no harm in giving cast brace with hinges for 6 weeks as protection.
3 horas
·
Me gusta
Bhavin Patel
Medial buttress plating required otherwise going to fail
Be careful go for delayed wt bearing
3 horas
·
Me gusta
·
1
Prasad Pidikiti
Very easy to criticise. But a good attempt
2 horas
·
Me gusta
Jithendran Iyer
articular incongrity +++
1 hora
·
Me gusta
Bhupendra Patel
Had similar case... 55 yr male.. open grade 3a
1 hora
·
Me gusta
Bhupendra Patel
Post op
1 hora
·
Me gusta
·
1
Vivek Mahajan
I think restoring medial buttress, better articular congruity and longer plate and compression at fracture site could have been better. Might need a medial plating with bone grafting in future.
41 min
·
Me gusta
Pankaj More
Very sincere efforts. Has to be appreciated .its really very bad intra articular comminuted fracture.
18 min
·
Me gusta
No hay comentarios:
Publicar un comentario
Entrada más reciente
Entrada antigua
Inicio
Suscribirse a:
Enviar comentarios (Atom)
No hay comentarios:
Publicar un comentario